Your go-to newsletter for technical updates and latest changes in refrigeration and industrial solutions—delivered nearly every month.
Danfoss Tech Insider keeps you up to date with the latest developments in the Cooling and Industrial Products portfolios from Danfoss Climate Solutions. Each edition offers a quick overview of key technical updates and product news, with direct links to relevant documentation and further details. Published monthly, Tech Insider ensures you’re always informed about the latest innovations and changes across our products and solutions. We hope you enjoy reading Danfoss Tech Insider and find it both useful and inspiring!
Table of contents
- New Superheat Controller Kit EKE 100 1VK
- Optyma™ Plus P00 – new NTZ A2L models for extended low‑temperature applications
- Market release of AK-CC25 Pro BT case controller
- New service cable for EKE 100/110 products
- Extension of the minimum frequency range to 20 Hz for HGX24 CO₂ T
- New and updated content
Commercial Refrigeration
New Superheat Controller Kit EKE 100 1VK
We are excited to announce the launch of our new superheat controller kit EKE 100 1VK, designed to bring convenience and efficiency to your cold room applications. This innovative solution simplifies the ordering and stocking processes, improves installation ease, and ensures fast and reliable performance.
The superheat controller kit includes the following components:
- EKE 100 1V Superheat controller & valve driver with integrated display
- DST P110 Pressure transmitter and cable
- AKS 11 Temperature sensor
- Bipolar coil for ETS 5M

Customers can also purchase an ETS 5M valve to complement the kit, depending on capacity needs. This comprehensive package is ideal for applications in air conditioning, commercial refrigeration, and food retail, providing precise superheat control and effectively regulating superheat to the lowest possible level in a short timeframe.
Benefits
- Simplified ordering and stocking
- Ease of installation with no missing parts
- Fast and reliable performance
- Energy consumption reduction, even amidst load variations
Ordering & availability
The superheat controller kit is now available for sales. Code number for ordering: SH Controller Kit EKE 100 1VK: 080G9100
More information
For detailed product information:
Optyma™ Plus P00 – new NTZ A2L models for extended low‑temperature applications
As part of our product range offering improvement, we are pleased to inform you that below aforementioned condensing units are all validated as standard with A2L refrigerants (factory setting).New model OP-LPVM096NTP00E has been launched to re-enforce the cooling capacity range product availability.


Details
Cooling capacity have been updated inside catalogue and will be release by week 51 inside CoolSelector. Installers shall ensure that the application envelopes are within the limits mentioned in instruction guideline and Coolselector. All instructions must be followed as provided in the Instruction Manual and user guide. For enhanced safety, the condensing units are equipped with built-in protections including high pressure, low pressure, and high discharge temperature safeguards refer Instructions and User guide for more detailed information.
More information
For instructions and usage with approved refrigerants, customer shall refer to the literatures available in Danfoss approved channels like Coolselector, Product store and here bellow:
New service cable for EKE 100/110 products
We are pleased to inform you about an important update regarding the service cable of EKE 100 and EKE 110 controllers. To ensure compatibility with the latest KoolKey version PV04, we are introducing a new service cable.
Product details
Current cable 080G5058 New cable 080G5067

The existing service cable (080G5058) will be phased out and replaced by the new service cable (080G5067). This change is necessary to maintain seamless communication between EKE 100/110 and KoolProg using KoolKey PV04.
Compability

Note: All new orders for KoolKey will be delivered with PV04 versions.
Affected controllers
- 080G5050 - Superheat controller and valve driver EKE 100 1V IP00
- 080G5051 - Superheat controller and valve driver EKE 100 1V IP20
- 080G5052 - Superheat controller and valve driver EKE 100 1V IP20 with display
- 080G5055 - Superheat controller and valve driver EKE 100 2V IP00
- 080G5056 - Superheat controller and valve driver EKE 100 2V IP20
- 080G5057 - Superheat controller and valve driver EKE 100 2V IP20 with display
- 080G5066 - Superheat controller and valve driver EKE 100 2V IP20
- 080G5059 - Injection controller EKE 110 1V IP20
Availability & ordering
For all future orders, please ensure that you order the new service cable (080G5067) instead of the previous cable (080G5058). This will guarantee compatibility and functionality when used with EKE 100/110 controllers, KoolKey, and the KoolProg PC tool.
The new service cable will be available for sale starting from week 5 of 2026.
Extension of the minimum frequency range to 20 Hz for HGX24 CO₂ T

We are pleased to announce that the HGX24 CO₂ T compressor series will be equipped with an extended frequency range in the future. The minimum operating frequency will be reduced to 20 Hz, matching the existing capabilities of the HGX34 CO₂ T, HGX46 CO₂ T, and HGX56 CO₂ T + LT transcritical CO₂ series.
Benefits for your applications
- Optimized partial load capacity for refrigeration and heat pump applications with high partial load requirements.
- Increased system efficiency through better adaptation to real operatingconditions.
- Product line harmonization for simplified system integration and control.

Please note that reliable oil return must be ensured when operating at low frequencies. The minimum frequency must be selected depending on the application and require careful coordination with the system components. We recommend to make adjustments in close consultation with your system design and control system.
Affected BOCK compressor ranges
- HGX24 CO₂ T (transcritical) / UL-HGX24 CO₂ T (transcritical)
- HGX24 P CO₂ T (with LSPM motors) / UL-HGX24 P CO₂ T (with LSPM motors)
- HGX24e CO₂ LT (subcritical) / UL-HGX24e CO₂ LT (subcritical)
Introduction
A new design key for compressors is being introduced to indicate the change. Compressors are assigned design key 085. The design key can be found on the compressor's nameplate (the least 3 characters of the machine number (No.)).
The minimum frequency of 20 Hz will be available for new compressor from the date of order receipt in calendar week 08/2026 (from February 16, 2026).
More information
- Selection software: BOCK VAP selection software: vap.bock.de
- BOCK Compressor Code Finder: Compressor Selector | Danfoss
- Product Store: store.danfoss.com
Food Retail
New Superheat Controller Kit EKE 100 1VK
We are excited to announce the launch of our new superheat controller kit EKE 100 1VK, designed to bring convenience and efficiency to your cold room applications. This innovative solution simplifies the ordering and stocking processes, improves installation ease, and ensures fast and reliable performance.
The superheat controller kit includes the following components:
- EKE 100 1V Superheat controller & valve driver with integrated display
- DST P110 Pressure transmitter and cable
- AKS 11 Temperature sensor
- Bipolar coil for ETS 5M

Customers can also purchase an ETS 5M valve to complement the kit, depending on capacity needs. This comprehensive package is ideal for applications in air conditioning, commercial refrigeration, and food retail, providing precise superheat control and effectively regulating superheat to the lowest possible level in a short timeframe.
Benefits
- Simplified ordering and stocking
- Ease of installation with no missing parts
- Fast and reliable performance
- Energy consumption reduction, even amidst load variations
Ordering & availability
The superheat controller kit is now available for sales. Code number for ordering: SH Controller Kit EKE 100 1VK: 080G9100
More information
For detailed product information:
Market release of AK-CC25 Pro BT case controller
Bluetooth-enabled AK-CC25 Pro BT – expansion of the new ADAP-KOOL® CC-25 case controller family
AK-CC25 Pro highlights
New modern design and improved user experience
- White LED display and backlit capacitive touch buttons to only show the relevant UI elements
- Built-in BLE for connectivity with AK-CC Connect mobile app for fast and easy service & commissioning (AK-CC25 Pro BT only)
- New and improved functions in the mobile app: FW update, performance dashboards, Wizard for guided field installation and commissioning (AK-CC25 Pro BT only)
Best-in class application coverage in a single variant
- Support for variable speed compressors, dual circuits, dual compressor
- Full parameter MT/LT switch for optimized performance
- Fully flexible I/O configuration for customized applications
Food safety & energy efficiency
- Robust design for reliable operation with minimum downtime
- VSC enables MTR for optimal temperature in a display cabinet
Improved connectivity and monitoring
- Modbus RS-485 built-in
- Modbus over Wi-Fi via external gateway
- BLE built-in (AK-CC25 Pro BT only)
Availability & ordering
The initial is limited to countries/customers in Europe and Turkey, as we are still working on production capacity ramp-up and regional compliance approvals (e.g. UL). The product store will reflect this.

EKC/AK-CC 2xx Phase out
With the launch of AK-CC25, the phase out process of the existing EKC 202 and AK-CC 2xx controllers has been initiated. Please discuss with your Danfoss sales contact about the transition plan and forecast.
New service cable for EKE 100/110 products
We are pleased to inform you about an important update regarding the service cable of EKE 100 and EKE 110 controllers. To ensure compatibility with the latest KoolKey version PV04, we are introducing a new service cable.
Product details
Current cable 080G5058 New cable 080G5067

The existing service cable (080G5058) will be phased out and replaced by the new service cable (080G5067). This change is necessary to maintain seamless communication between EKE 100/110 and KoolProg using KoolKey PV04.
Compability

Note: All new orders for KoolKey will be delivered with PV04 versions.
Affected controllers
- 080G5050 - Superheat controller and valve driver EKE 100 1V IP00
- 080G5051 - Superheat controller and valve driver EKE 100 1V IP20
- 080G5052 - Superheat controller and valve driver EKE 100 1V IP20 with display
- 080G5055 - Superheat controller and valve driver EKE 100 2V IP00
- 080G5056 - Superheat controller and valve driver EKE 100 2V IP20
- 080G5057 - Superheat controller and valve driver EKE 100 2V IP20 with display
- 080G5066 - Superheat controller and valve driver EKE 100 2V IP20
- 080G5059 - Injection controller EKE 110 1V IP20
Availability & ordering
For all future orders, please ensure that you order the new service cable (080G5067) instead of the previous cable (080G5058). This will guarantee compatibility and functionality when used with EKE 100/110 controllers, KoolKey, and the KoolProg PC tool.
The new service cable will be available for sale starting from week 5 of 2026.
Video updates
Technical literature new and updated
Commerial refrigeration/Sensing solutions
- Brochure: Optyma™ condensing units for Europe
- Brochure: Superheat Controller Kit Brochure - EKE 100
- Brochure: DST G-series gas sensors brochure
- Brochure: DST P070 pressure sensors - the compact and reliable solution for HVAC industry
- White paper: Turning cooling into heating - How CO2 refrigeration powers 100% space heating
- Data Sheet: Gas sensor DST G300
- Data Sheet: Solenoid valve, EVT
- Data Sheet: Pressure transmitter, DST P070
- Data Sheet: Pressure Switch, KP-E
- Data Sheet: Solenoid valve, CSV 2 - CSV 15
- Data Sheet: Shut-off ball valve Type GBC M
- Data Sheet: DST G4yf
- Data Sheet: Hermetic receiver filter drier, DMC / DCC
- Data Sheet: Gas sensor, DST G4ze
- Data Sheet: Hermetic burn-out filter drier, DAS
- Data Sheet: Pressure transmitter, MBS 5100 / MBS 5150
- Data Sheet: Danfoss CDS203 Drive for VZN Compressors
- Product Declaration: EPD for Temperature Switch, Thermostat, RT14
- Product Declaration: EPD for Pressure switch, RT6AES
- Application guide: Optyma™ iCO2 condensing units R744 - 50 Hz 20kW
- Application guide: Maneurop® reciprocating compressors MT and MTZ
- Application guide: Scroll compressors PSH052 to PSH105
Industrial refrigeration
All information, including but not limited to information regarding product selection, application or use, product design, weight, dimensions, capacity, or any other technical data of products in product manuals, catalog descriptions, advertisements, etc., whether provided in writing, verbally, electronically, online, or via download, is to be considered purely informative and is binding only if and to the extent explicitly referenced in a quotation or order confi- mation. Danfoss assumes no responsibility for possible errors in catalogs, brochures, videos, and other printed materials. Danfoss reserves the right to make changes to its products without prior notice. This also applies to products already ordered but not delivered, provided such adjustments are possible with-out substantially changing the form, suitability, or function of the product. All trademarks contained in this publication are owned by Danfoss A/S or Danfoss group companies. Danfoss and the Danfoss logo are trademarks of Danfoss A/S. All rights reserved.