One drive for a wide range of applications

VACON® 100 INDUSTRIAL is full of features and dedicated for a wide range of constant power/torque applications. The easy-to-use and robust motor controls improve the reliability and efficiency of all AC motor types, including induction and permanent magnet and synchronous reluctance motors.

Integrated RS485 and Ethernet interfaces support all major industrial protocols making VACON 100 INDUSTRIAL easy to incorporate into all major control systems. The built-in PLC functionality enables integration of new functionality into the drive. Functional safety is improved with Safe Torque Off, which prevents the motor from generating torque on the motor shaft, Safe Stop 1 and ATEX-certified motor over-temperature protection.

The wall-mountable drive modules are easy to install and operate, and the enclosed drives are provided with a wide range of integrated options.

Supply voltages and power range

  • 208-240 V...0.55-90 kW
  • 380-500 V...1.1-630 kW
  • 525-690 V...5.5-800 kW

Features and benefits

Easy integration with plant automation due to extensive range of fieldbus options

High reliability in challenging environments as a result of conformal coating

Extended drive lifetime thanks to film capacitors

No additional accessories are required due to integrated RFI filters and DC choke

Documents

Type Name Language Valid for Updated Download File type
Brochure - AD Danfoss Drives Product Overview English (US) Multiple 21 Dec, 2018 2.2 MB PDF
Brochure - AD Marine - Certified for plain sailing English (US) Multiple 29 May, 2018 9.1 MB PDF
Installation guide - AN MC02 to MC04 Kit Instruction No language Multiple 30 May, 2013 519.9 KB PDF
Brochure - AD Mining and minerals AC drives English (US) Multiple 19 Feb, 2019 6.2 MB PDF
Installation guide - AN MR8 MR9 Conversion Kit Instruction No language Multiple 30 Nov, 2015 4.1 MB PDF
Installation guide - AN RFI filter installation manual No language Multiple 24 Jul, 2017 973.9 KB PDF
Installation guide - AN Vacon 100 and FLOW Supply Switch instr. No language Multiple 04 Apr, 2017 6.2 MB PDF
Installation guide - AN Vacon 100 Quick Guide No language Multiple 15 Dec, 2017 3.9 MB PDF
Safety guide - BH Vacon Safety Guide No language Multiple 02 Oct, 2017 359.2 KB PDF
Brochure - AD VACON® 100 Selection Guide English (US) Multiple 15 Mar, 2017 2.0 MB PDF

Drawings

Type Name Language Updated Download File type
M-Drawing - MD MCAD VACON 100 Flange Mounting MR4 IP54 No language 01 Aug, 2018 2.2 MB ZIP
M-Drawing - MD MCAD VACON 100 Flange Mounting MR5 IP54 No language 01 Aug, 2018 2.5 MB ZIP
M-Drawing - MD MCAD VACON 100 Flange Mounting MR6 IP54 No language 01 Aug, 2018 2.9 MB ZIP
M-Drawing - MD MCAD VACON 100 Flange Mounting MR7 IP54 No language 01 Aug, 2018 2.5 MB ZIP
M-Drawing - MD MCAD VACON 100 Flange Mounting MR8 IP00 No language 01 Aug, 2018 908.2 KB ZIP
M-Drawing - MD MCAD VACON 100 Flange Mounting MR9 IP00 No language 01 Aug, 2018 668.4 KB ZIP
M-Drawing - MD MCAD VACON 100 Main Switch MR4 IP54 No language 01 Dec, 2016 2.2 MB ZIP
M-Drawing - MD MCAD VACON 100 Main Switch MR4 IP54 No language 01 Dec, 2016 2.6 MB DXF
M-Drawing - MD MCAD VACON 100 Main Switch MR4 IP54 No language 01 Dec, 2016 209.9 KB PDF
M-Drawing - MD MCAD VACON 100 Main Switch MR5 IP54 No language 01 Dec, 2016 2.3 MB ZIP
M-Drawing - MD MCAD VACON 100 Main Switch MR5 IP54 No language 01 Dec, 2016 2.5 MB DXF
M-Drawing - MD MCAD VACON 100 Main Switch MR5 IP54 No language 01 Dec, 2016 167.9 KB PDF
M-Drawing - MD MCAD VACON 100 Main Switch MR6 IP54 No language 01 Dec, 2016 2.0 MB ZIP
M-Drawing - MD MCAD VACON 100 Main Switch MR6 IP54 No language 01 Dec, 2016 2.7 MB DXF
M-Drawing - MD MCAD VACON 100 Main Switch MR6 IP54 No language 01 Dec, 2016 170.0 KB PDF
M-Drawing - MD MCAD VACON 100 Main Switch MR7 IP54 No language 01 Dec, 2016 1.5 MB ZIP
M-Drawing - MD MCAD VACON 100 Main Switch MR7 IP54 No language 01 Dec, 2016 3.8 MB DXF
M-Drawing - MD MCAD VACON 100 Main Switch MR7 IP54 No language 01 Dec, 2016 146.9 KB PDF
M-Drawing - MD MCAD VACON 100 MR10 IP00 No language 01 Dec, 2016 877.8 KB DXF
M-Drawing - MD MCAD VACON 100 MR10 IP00 No language 01 Dec, 2016 665.6 KB DXF
M-Drawing - MD MCAD VACON 100 MR10 IP00 No language 01 Dec, 2016 716.2 KB PDF
M-Drawing - MD MCAD VACON 100 MR4 IP54 No language 01 Dec, 2016 1.8 MB ZIP
M-Drawing - MD MCAD VACON 100 MR4 IP54 No language 01 Dec, 2016 9.3 MB DXF
M-Drawing - MD MCAD VACON 100 MR4 IP54 No language 01 Dec, 2016 13.9 MB DXF
M-Drawing - MD MCAD VACON 100 MR4 IP54 No language 01 Dec, 2016 570.4 KB PDF
M-Drawing - MD MCAD VACON 100 MR5 IP54 No language 01 Dec, 2016 1.9 MB ZIP
M-Drawing - MD MCAD VACON 100 MR5 IP54 No language 01 Dec, 2016 8.9 MB DXF
M-Drawing - MD MCAD VACON 100 MR5 IP54 No language 01 Dec, 2016 13.9 MB DXF
M-Drawing - MD MCAD VACON 100 MR5 IP54 No language 01 Dec, 2016 576.2 KB PDF
M-Drawing - MD MCAD VACON 100 MR6 IP54 No language 01 Dec, 2016 1.7 MB ZIP
M-Drawing - MD MCAD VACON 100 MR6 IP54 No language 01 Dec, 2016 9.3 MB DXF
M-Drawing - MD MCAD VACON 100 MR6 IP54 No language 01 Dec, 2016 14.6 MB DXF
M-Drawing - MD MCAD VACON 100 MR6 IP54 No language 01 Dec, 2016 582.7 KB PDF
M-Drawing - MD MCAD VACON 100 MR7 IP54 No language 01 Dec, 2016 1.2 MB ZIP
M-Drawing - MD MCAD VACON 100 MR7 IP54 No language 01 Dec, 2016 3.8 MB DXF
M-Drawing - MD MCAD VACON 100 MR7 IP54 No language 01 Dec, 2016 3.8 MB DXF
M-Drawing - MD MCAD VACON 100 MR7 IP54 No language 01 Dec, 2016 585.3 KB PDF
M-Drawing - MD MCAD VACON 100 MR8 IP00 No language 01 Dec, 2016 687.9 KB ZIP
M-Drawing - MD MCAD VACON 100 MR8 IP00 No language 01 Dec, 2016 4.4 MB DXF
M-Drawing - MD MCAD VACON 100 MR8 IP00 No language 01 Dec, 2016 6.4 MB DXF
M-Drawing - MD MCAD VACON 100 MR8 IP00 No language 01 Dec, 2016 985.0 KB PDF
M-Drawing - MD MCAD VACON 100 MR8 IP54 No language 01 Dec, 2016 421.5 KB ZIP
M-Drawing - MD MCAD VACON 100 MR8 IP54 No language 01 Dec, 2016 3.7 MB DXF
M-Drawing - MD MCAD VACON 100 MR8 IP54 No language 01 Dec, 2016 3.9 MB DXF
M-Drawing - MD MCAD VACON 100 MR8 IP54 No language 01 Dec, 2016 3.5 MB DXF
M-Drawing - MD MCAD VACON 100 MR8 IP54 No language 01 Dec, 2016 271.5 KB PDF
M-Drawing - MD MCAD VACON 100 MR8 IP54 UL No language 01 Aug, 2018 429.8 KB ZIP
M-Drawing - MD MCAD VACON 100 MR9 IP00 No language 01 Dec, 2016 481.7 KB ZIP
M-Drawing - MD MCAD VACON 100 MR9 IP00 No language 01 Dec, 2016 4.0 MB DXF
M-Drawing - MD MCAD VACON 100 MR9 IP00 No language 01 Dec, 2016 6.3 MB DXF
M-Drawing - MD MCAD VACON 100 MR9 IP00 No language 01 Dec, 2016 445.4 KB PDF
M-Drawing - MD MCAD VACON 100 MR9 IP54 No language 01 Dec, 2016 553.7 KB ZIP
M-Drawing - MD MCAD VACON 100 MR9 IP54 No language 01 Dec, 2016 2.7 MB DXF
M-Drawing - MD MCAD VACON 100 MR9 IP54 No language 01 Dec, 2016 2.1 MB DXF
M-Drawing - MD MCAD VACON 100 MR9 IP54 No language 01 Dec, 2016 9.8 MB DXF
M-Drawing - MD MCAD VACON 100 MR9 IP54 No language 01 Dec, 2016 1.4 MB PDF
M-Drawing - MD MCAD VACON 100 MR9 IP54 UL No language 01 Aug, 2018 553.0 KB ZIP

Software

Type Name Language Updated Version Status Download File type
Fieldbus Configuration Files VACON® 100 EtherNet/IP EDS No language 05 Nov, 2018 RL 38.6 KB ZIP
AC Drive Firmware VACON® 100 INDUSTRIAL Firmware No language 06 Jun, 2018 029 RL 6.6 MB ZIP
Fieldbus Configuration Files VACON® 100 PROFINET IO GSDML No language 28 Oct, 2016 RL 54.7 KB ZIP
Fieldbus Configuration Files VACON® 100 PROFINET IO GSDML No language 05 Nov, 2018 RL 58.4 KB ZIP
Fieldbus Configuration Files VACON® 100 SIMATIC PDM PROFINET IO EDD No language 31 Jan, 2017 RL 111.2 KB ZIP
Software Tools VACON® Live No language 25 Sep, 2017 1.1.17.0 RL 58.8 MB ZIP
Fieldbus Firmware VACON® OPT-C3/C5 PROFIBUS DP Firmware No language 07 Oct, 2015 018 RL 57.6 KB ZIP
Fieldbus Firmware VACON® OPT-C6 CANopen Firmware No language 21 Aug, 2017 026 RL 74.5 KB ZIP
Fieldbus Firmware VACON® OPT-C7 DeviceNet Firmware No language 18 Sep, 2012 012 RL 81.8 KB ZIP
Fieldbus Firmware VACON® OPT-E3/E5 PROFIBUS DP Firmware No language 04 Oct, 2018 007 RL 2.5 MB ZIP
Fieldbus Configuration Files VACON® OPTE3/E5 PROFIBUS GSD No language 31 Mar, 2017 RL 13.4 KB ZIP
Fieldbus Configuration Files VACON® OPTE6 CANopen EDS No language 06 Sep, 2018 RL 108.2 KB ZIP
Fieldbus Firmware VACON® OPT-E6 CANopen Firmware No language 03 Oct, 2018 011 RL 2.8 MB ZIP
Fieldbus Configuration Files VACON® OPTE7 DeviceNet EDS No language 21 Jan, 2015 RL 3.1 KB ZIP
Fieldbus Firmware VACON® OPT-E7 DeviceNet Firmware No language 26 Jan, 2015 005 RL 1.8 MB ZIP
Fieldbus Firmware VACON® OPT-E9 DualPort Ethernet Firmware No language 24 Jan, 2018 009 RL 6.9 MB ZIP
Fieldbus Configuration Files VACON® OPTE9 EtherNet/IP EDS No language 15 Mar, 2018 RL 67.9 KB ZIP
Fieldbus Configuration Files VACON® OPTE9 PROFINET IO GSDML No language 16 Jan, 2018 RL 145.2 KB ZIP
Fieldbus Configuration Files VACON® OPTE9 SIMATIC PDM EDD No language 30 Jun, 2017 RL 436.6 KB ZIP
Fieldbus Configuration Files VACON® OPTE9/EA EtherNet/IP AOI No language 16 Feb, 2018 RL 531.9 KB ZIP
Fieldbus Firmware VACON® OPTEA Adv. DualPort Eth. Firmware No language 13 Nov, 2018 003 RL 7.2 MB ZIP
Fieldbus Configuration Files VACON® OPTEA EtherNet/IP EDS No language 11 Sep, 2018 RL 40.4 KB ZIP
Fieldbus Configuration Files VACON® OPTEA EtherNet/IP EDS No language 13 Nov, 2018 RL 54.0 KB ZIP
Fieldbus Configuration Files VACON® OPTEA PROFINET IO GSDML No language 11 Sep, 2018 RL 23.3 KB ZIP
Fieldbus Configuration Files VACON® OPTEA PROFINET IO GSDML No language 13 Nov, 2018 RL 23.6 KB ZIP
Fieldbus Configuration Files VACON® OPTEA SIMATIC PDM EDD No language 13 Nov, 2018 RL 461.7 KB ZIP
Fieldbus Configuration Files VACON® OPTEC EtherCAT ESI No language 04 Apr, 2018 RL 151.5 KB ZIP
Fieldbus Firmware VACON® OPT-EC EtherCAT Firmware No language 20 Apr, 2018 003 RL 2.5 MB ZIP
Fieldbus Configuration Files VACON® TIA Portal Function Blocks No language 16 Feb, 2018 RL 2.9 MB ZIP

Related applications

Fans, pumps, conveyors, compressors, steering gear, chippers and extrudes.

  • Drives for industrial pumps

    By controlling industrial pumps with a Danfoss AC drive you can help optimize processes and significantly reduce energy and maintenance costs.

  • Drives for industrial fans

    With Danfoss AC drives solutions for industrial ventilation you enjoy the benefits of high precision, user-friendly interfaces, distributed intelligence and low operating costs.

  • Drives for industrial compressors

    Achieve significantly lower energy consumption and lower operating costs, using Danfoss AC drives to continually adjust the compressor capacity to the actual heat load and process needs.

  • Drives for marine pumps and separators
    Drives for marine pumps and separators

    For reliable operation, reduced emissions, and long life of marine pumps and separators, draw upon engineering knowhow from Danfoss.

Case studies

  • Improved process control for Valio
    Improved process control for Valio

    100 VACON® 100 drives enable accurate control of production line and improve work safety and reliability.

  •  Quintex chooses VACON® drives 3,500 times
    Quintex chooses VACON® drives 3,500 times

    Over 6000 VACON® drives have ensured high energy savings in more than 3500 energy management and safety systems.