Detection of low pressure level in the charge pump is important to provide enough fluid to cool down the pumps/motors as well as compensate for any internal leakages in the system. The solution is to use a pressure transmitter mounted on the pumps connected to the main control unit ensuring that the pressure do not drop below the lower warning level.