Thermal valves

  • Overview
  • Product range
  • Documents

Domestic Hot Water systems require a special approach to hydronic balancing. As any other heating system, the water should be equally distributed. But because the water is also consumed, safety matters too. It is important to control the water temperature. It should be high enough to use and avoid growth of legionella bacteria, but not so high that it causes personal injuries. At the same time, the energy efficiency of the DHW system needs to be optimized.

For these reasons, manual or automatic balancing valves are not applicable. Thermal balancing valves, controlling the water temperature in every riser of the system, are the best option for these types of systems. By maintaining a constant water temperature in every riser, the DHW system is automatically balanced, no matter the distance to the DHW source.

For extra safety, DHW systems can periodically be disinfected by temporarily increasing the water temperature to a level that kills legionella bacteria.

Danfoss offers a broad range of thermal balancing valves, disinfection solutions and related products for Domestic Hot Water systems.

Features and benefits

Improve comfort

Thermal balancing ensures hot water to be available equally fast at the same temperatures, no matter how far from the source

Save energy

Heat losses are minimized, and the circulation pump only distributes the required amount of water to minimize the energy consumption of the system

Reduce water waste

Hot water is always available and reduces long waiting times

Reduce the risk of legionella

Insufficient heated risers that allow legionella to grow are prevented but the functional design of the system remains just as important

Product range

  • if (isSmallPicture) { Danfoss Thermal balancing valve MTCV; } else if (isBigColumns) { Danfoss Thermal balancing valve MTCV } else { Danfoss Thermal balancing valve MTCV }
    MTCV Thermal balancing valves

    MTCV Thermal balancing valves provide a dynamic, temperature based, balancing solution for drinking water applications. The valves prevent too high temperatures causing lime, corrosion and high energy costs. They also prevent too low temperatures where legionella risks increase and long waiting times for hot water to occur.

Documents

Documents
Type Name Language Valid for Updated Download File type
Brochure Energy saving solutions for renovation of heating and cooling systems Romanian, Moldavian, Moldovan Romania 01 Sept, 2014 6.4 MB .pdf
Brochure Energy saving solutions for renovation of heating and cooling systems Hungarian Hungary 01 Sept, 2014 6.4 MB .pdf
Brochure Energy saving solutions for renovation of heating and cooling systems English Multiple 10 Sept, 2014 5.9 MB .pdf
Brochure Energy saving solutions for renovation of heating and cooling systems Polish Multiple 19 Feb, 2019 5.9 MB .pdf