CZECH REPUBLIC: Rarely is reliable uptime so critical, as during continuous casting at a steelworks. To ensure reliable 24/7 operation of continuous casting, system integrator Ingeteam chose VACON® NXP drives to regulate the electromagnetic stirring (EMS) process at the renowned Třinecké železárny a.s., the largest steelworks in the Czech Republic.

Non-stop
Discover how Danfoss ensures 24/7 reliability in continuous casting
Read the case study
The Třinecké železárny steelworks has relied upon VACON® drives to regulate pumps, conveyors and hoists for many years. The plant operators have built up long experience and appreciate the good programmability and ease of maintenance of these drives. They are well-suited to the harsh environment in this heavy industry, and have demonstrated robust performance and long lifetime, many times over.
In 2018 the steelworks renovated its electromagnetic stirring (EMS) process in the continuous casting plant. In this retrofit project, VACON® NXP Standalone Drives were installed to replace a series of twenty-year-old drives from New Zealand.
The electromagnetic stirring process (EMS) involves a rotating magnetic field in huge coils. Liquid steel passes through the coil, which acts like a stator to give the liquid steel a rotational movement. This process ensures better quality of the casted product.
With the retrofit, nine VACON® NXP Standalone Drives equipped with PROFIBUS communication were installed to control the rotating magnetic field, to maintain a frequency range of 3-5 Hz and nominal 300 A current.

Dedicated EMS control solution for the metal industry
The electromagnetic stirring process (EMS) involves a rotating magnetic field in huge coils. Liquid steel passes
through the coil, which acts like a stator to give the liquid steel a rotational movement. This process ensures better quality of the casted product.
With the retrofit, nine VACON® NXP Standalone Drives equipped with PROFIBUS communication were installed to control the rotating magnetic field, to maintain a frequency range of 3-5 Hz and nominal 300 A current. This dedicated solution has been developed specifically for optimal control of the EMS application.

100% reliability, easy serviceability and local presence
“We chose Ingeteam with Danfoss VACON® drives because they offered us the most robust solution, with 100% reliable 24/7 performance. Serviceability of the standalone drives is easy, which is vital for our steelworks in scheduled maintenance situations.
Best of all, Danfoss Drives offers us the presence of a local service and application team who participated actively throughout the planning, installation and commissioning, and who can support us with the regular service to keep the EMS process performing optimally.”
– Michal Podermanski, Project Manager, Třinecké železárny a.s.
Třinecké železárny a.s.
Established in 1839, Třinecké železárny
a.s. is the largest steel producer in the Czech Republic, exporting to more than 60 countries globally. Since its establishment, Třinecké železárny has produced approximately 180 million tons of steel. The steelworks is an important element of the region and the town of Třinec, which has changed from a small agricultural village to a considerable town, especially thanks
to Třinecké železárny. Known locally as Werk, the company supports the Czech Extra-league Ice-hockey team HC Oceláři Třinec and numerous other cultural, sport, and educational activities.

Learn about the standalone drives

Learn about the drives
Read more about drives for industrial applications
It is mandatory that Danfoss AC drives are certified by the world’s leading classification authorities. See below for a brief description of the marine type approvals and to download the certificates.

Whatever your water system ambition, iC7-Aqua delivers it. The next-generation variable frequency drive for water applications improves pump efficiency, energy performance, and power quality across modern water infrastructure.

Variable speed control with AC drives enables you to reduce energy consumption by running compressor applications at a lower speed.

Improve your COP and save on energy consumption by applying Danfoss AC drives to optimize the capacity control of refrigeration compressors, condensers and evaporators.

Compressor speed control provides constant pressure regulation as well as reducing your energy consumption, especially for part-load operation.

Variable speed control of a chiller allows you to provide constant pressure regulation while matching the capacity to the actual need based on measurements in the system. Speed control is beneficial when a compressor runs for long periods at partial load. Reduce operational costs by running applications at a lower speed which reduces energy consumption. And reduce installation costs by optimizing the system and the compressor itself.