In every district heating utility, combined heat and power plant, distribution network and substation, there is a need for on/off control of the building system connection.

With on/off regulation (opening and closing) shut-off valves create sectioning of the system that enables service, maintenance and repairs to be carried out in sections, without shutting down and emptying the whole system.

When using special types of ball valves (hot tap and branching), the network can be expanded while the system is fully operational.

Danfoss JIP ball valves have optimum flow design that is represented by guiding pipes and pipe insert in the ball which ensures smooth flow through the ball eliminating cavitation and achieving a lower pressure drop.

The outcomes are lower operating costs, lower CO2 emissions and energy savings.

The Danfoss high performance ball valves are specially designed for district heating plants, distribution and transmission networks, pumps and substations.

Having fully welded bodies, the steel ball valves meet the requirements for valves used in hot water systems thus offering a high degree of security. Furthermore, the ball valves are suitable for district cooling systems.

Features and benefits

Up to 30% energy savings and low operating costs due to unique flow design of the ball valves that ensures low pressure drop and low pump power consumption.

Expected to achieve the same lifetime as the pipeline itself, which is from 25 to 35 years, depending on the conditions

Reliable and maintenance free sealing during the lifetime

Easy to open and close due to independence from axial forces and a unique break loose system

Life-long external tightness thanks to a unique PTFE / carbon stem packing box that prevents external leakage

A sophisticated spring construction provides optimum internal tightness and ensures Class A leakage rates throughout the product's lifetime

Documents

Type Name Language Updated Download File type
Brochure - AD Alacsony nyomásesés és energiamegtakarítás Hungarian 22 Mar, 2018 2.5 MB .pdf
Brochure - AD Ball valves for heating and district heating Russian 22 Mar, 2018 1.2 MB .pdf
Data sheet - AI Full bore JIP™ ball valves (PN 16/25/40) Romanian, Moldavian, Moldovan 22 Mar, 2018 956.1 KB .pdf
Data sheet - AI Full bore JIP™ ball valves (PN 16/25/40) Polish 22 Mar, 2018 960.1 KB .pdf
Data sheet - AI Full bore JIP™ ball valves (PN 16/25/40) Czech 22 Mar, 2018 956.2 KB .pdf
Data sheet - AI Full bore JIP™ ball valves (PN 16/25/40) German 22 Mar, 2018 1.0 MB .pdf
Data sheet - AI Full bore JIP™ ball valves (PN 16/25/40) Danish 22 Mar, 2018 944.1 KB .pdf
Data sheet - AI Full bore JIP™ ball valves (PN 16/25/40) French 22 Mar, 2018 965.6 KB .pdf
Data sheet - AI Full bore JIP™ ball valves (PN 16/25/40) Estonian 22 Mar, 2018 940.9 KB .pdf
Data sheet - AI Full bore JIP™ ball valves (PN 16/25/40) Serbian (RS) 22 Mar, 2018 898.1 KB .pdf
Data sheet - AI Full bore JIP™ ball valves (PN 16/25/40) Latvian 22 Mar, 2018 973.4 KB .pdf
Data sheet - AI Full bore JIP™ ball valves (PN 16/25/40) Croatian 22 Mar, 2018 948.3 KB .pdf
Data sheet - AI Full bore JIP™ ball valves (PN 16/25/40) Swedish 22 Mar, 2018 943.2 KB .pdf
Data sheet - AI Full bore JIP™ ball valves (PN 16/25/40) Lithuanian 22 Mar, 2018 951.2 KB .pdf
Data sheet - AI Full bore JIP™ ball valves (PN 16/25/40) English 22 Mar, 2018 954.6 KB .pdf
Data sheet - AI Full bore JIP™ ball valves (PN 16/25/40) Finnish 22 Mar, 2018 894.5 KB .pdf
Data sheet - AI Full bore JIP™ ball valves (PN 16/25/40) Bulgarian 22 Mar, 2018 944.3 KB .pdf
Data sheet - AI Hot tap JIP balll valves Latvian 22 Mar, 2018 575.9 KB .pdf
Data sheet - AI Hot tap JIP balll valves Croatian 22 Mar, 2018 546.8 KB .pdf
Data sheet - AI Hot tap JIP balll valves Polish 22 Mar, 2018 562.4 KB .pdf
Data sheet - AI Hot tap JIP balll valves Lithuanian 22 Mar, 2018 557.5 KB .pdf
Data sheet - AI Hot tap JIP balll valves Romanian, Moldavian, Moldovan 22 Mar, 2018 553.6 KB .pdf
Data sheet - AI Hot tap JIP balll valves Danish 22 Mar, 2018 500.7 KB .pdf
Data sheet - AI Hot tap JIP balll valves Swedish 22 Mar, 2018 547.1 KB .pdf
Data sheet - AI Hot tap JIP balll valves Finnish 22 Mar, 2018 496.8 KB .pdf
Data sheet - AI Hot tap JIP balll valves Serbian (RS) 22 Mar, 2018 550.3 KB .pdf
Data sheet - AI Hot tap JIP balll valves German 22 Mar, 2018 660.9 KB .pdf
Data sheet - AI Hot tap JIP balll valves English 22 Mar, 2018 607.8 KB .pdf
Data sheet - AI HT German 22 Mar, 2018 9.0 MB .pdf
Data sheet - AI HT French 22 Mar, 2018 3.5 MB .pdf
Data sheet - AI JIP-FF/FW/WW/II/IW Lithuanian 22 Mar, 2018 2.9 MB .pdf
Data sheet - AI JIP-FF/FW/WW/II/IW Chinese (CN) 22 Mar, 2018 899.9 KB .pdf
Brochure - AD Opriți pierderile de presiune, începeți economisirea energiei Romanian, Moldavian, Moldovan 22 Mar, 2018 14.2 MB .pdf
Brochure - AD Shut off the pressure loss open up for energy savings Danish 22 Mar, 2018 1.9 MB .pdf
Brochure - AD Shut off the pressure loss open up for energy savings English 22 Mar, 2018 1.7 MB .pdf
Brochure - AD Shut off the pressure loss open up for energy savings Czech 22 Mar, 2018 1.6 MB .pdf
Brochure - AD Shut off the pressure loss open up for energy savings Slovenian 22 Mar, 2018 1.5 MB .pdf
Data sheet - AI Standard JIP™ ball valves English 22 Mar, 2018 1.5 MB .pdf
Data sheet - AI Standard JIP™ ball valves Swedish 22 Mar, 2018 1.4 MB .pdf
Data sheet - AI Standard JIP™ ball valves Czech 22 Mar, 2018 1.4 MB .pdf
Data sheet - AI Standard JIP™ ball valves Croatian 22 Mar, 2018 1.4 MB .pdf
Data sheet - AI Standard JIP™ ball valves Estonian 22 Mar, 2018 1.4 MB .pdf
Data sheet - AI Standard JIP™ ball valves Latvian 22 Mar, 2018 1.4 MB .pdf
Data sheet - AI Standard JIP™ ball valves Romanian, Moldavian, Moldovan 22 Mar, 2018 1.4 MB .pdf
Data sheet - AI Standard JIP™ ball valves French 22 Mar, 2018 1.4 MB .pdf
Data sheet - AI Standard JIP™ ball valves Serbian (RS) 22 Mar, 2018 1.4 MB .pdf
Data sheet - AI Standard JIP™ ball valves German 22 Mar, 2018 1.5 MB .pdf
Data sheet - AI Standard JIP™ ball valves Finnish 22 Mar, 2018 1.4 MB .pdf
Data sheet - AI Standard JIP™ ball valves Danish 22 Mar, 2018 1.4 MB .pdf
Data sheet - AI Standard JIP™ ball valves Bulgarian 22 Mar, 2018 1.4 MB .pdf
Data sheet - AI Standard JIP™ ball valves Lithuanian 22 Mar, 2018 1.4 MB .pdf
Data sheet - AI Standard JIP™ ball valves Polish 22 Mar, 2018 1.4 MB .pdf
Brochure - AD Zníženie úbytku tlaku - Cesta k úsporám energie Slovak 22 Mar, 2018 1.6 MB .pdf
Data sheet - AI Краны шаровые JIP STANDARD Russian 22 Mar, 2018 198.2 KB .pdf
Data sheet - AI Краны шаровые JiP, цельносварные из углеродистой стали со стандартным проходом Russian 22 Mar, 2018 820.8 KB .pdf
Data sheet - AI Полнопроходные шаровые краны JIP FB Ukrainian 22 Mar, 2018 1.3 MB .pdf
Data sheet - AI Таблиця вибору електронних регуляторів ECL Comfort Ukrainian 22 Mar, 2018 3.2 MB .pdf
Data sheet - AI Шаровые краны JIP Ukrainian 22 Mar, 2018 2.8 MB .pdf

Selection tool

Application tool

FAQ

Can Danfoss JIP ball valves be used in oil and gas applications?

Danfoss JIP ball valves are specially designed for district heating and cooling applications and should not be used with media like gas and oil because the valves are approved for fluid group 2 (PED 97/23/EG).

Can Danfoss JIP ball valves be used for other purposes than district heating and cooling?

Danfoss JIP ball valves are specially designed for district heating and cooling applications. For special applications, please contact your local Danfoss sales office to consult about the precise application information.

Can Danfoss JIP ball valves be used for controlling the flow?

Ball valves are shut-off valves and must as such always be in a complete opened or closed position. If the ball valve is used to control the flow, cavitation and potential damage of the ball surface (particles in media) can decrease the lifetime of the product and result in unstable system flow control.

How can you save on CO2 emissions and energy with a simple product like ball valves?

Danfoss JIP ball valves have a special internal design that enables optimum flow of the working medium with minimum pressure loss. With lower pressure loss the pumping energy in a system can be accordingly reduced resulting in lower energy consumption and C02 emissions.

In which positions can ball valves be installed?

Danfoss JIP ball valves can be installed in all positions.

Videos